SMA
|
|
Input Values (208V) |
|
|
|
Recommended max PV Power |
PPV |
6500 Wp STC |
|
Max DC Power |
PDC, max |
5500 Wp PTC |
|
DC Input Voltage Range |
VDC |
207 to 600 VDC |
|
MPP Tracking Voltage Range |
VPV |
207 to 550 VDC |
|
PV Start Voltage |
VPV |
270 VDC |
|
Max input current |
IPV, max |
25 A |
|
DC Voltage ripple |
VPP |
< 5% |
|
DC Disconnectors |
|
Optional external DC Disconnect/Breaker |
|
Pole confusion protection |
|
Short Circuit diode |
|
Ground fault protection |
IDif |
> 1000 mA |
|
Input Values (240V) |
|
|
|
Recommended max PV Power |
PPV |
7500 Wp STC |
|
Max DC Power |
PDC, max |
6300 Wp PTC |
|
DC Input Voltage Range |
VDC |
234 to 600 VDC |
|
MPP Tracking Voltage Range |
VPV |
234 to 550 VDC |
|
PV Start Voltage |
VPV |
300 VDC |
|
Max input current |
IPV, max |
25 A |
|
DC Voltage ripple |
VPP |
< 5% |
|
DC Disconnect |
|
Optional external DC Disconnect/Breaker |
|
Pole confusion protection |
|
Short Circuit diode |
|
Ground fault protection |
IDif |
> 1000 mA |
|
Input Values (277V) |
|
|
|
Recommended max PV Power |
PPV |
7500 Wp STC |
|
Max DC Power |
PDC, max |
6300 Wp PTC |
|
DC Input Voltage Range |
VDC |
234 to 600 VDC |
|
MPP Tracking Voltage Range |
VPV |
234 to 550 VDC |
|
PV Start Voltage |
VPV |
300 VDC |
|
Max input current |
IPV, max |
25 A |
|
DC Voltage ripple |
VPP |
< 5% |
|
DC Disconnect |
|
Optional external DC Disconnect/Breaker |
|
Pole confusion protection |
|
Short Circuit diode |
|
Ground fault protection |
IDif |
> 1000 mA |
|
Output Values (208V) |
|
|
|
Max AC Power |
PAC |
5200 W |
|
Total Harmonic Distortion |
THDIAC |
< 4% (With KVgrid < 2% and PAC > 0.5 PACnom) |
|
Operating Range, Grid Voltage |
VAC |
183 V to 229 V |
|
Operating Range, Grid Frequency |
fAC |
59.3 Hz - 60.5 Hz |
|
Phase Shift (Ref. Fundamental) |
cos(phi) |
0° |
|
Output Values (240V) |
|
|
|
Max AC Power |
PAC |
6000 W |
|
Total Harmonic Distortion |
THDIAC |
< 4% (With KVgrid < 2% and PAC > 0.5 PACnom) |
|
Operating Range, Grid Voltage |
VAC |
211 V to 264 V |
|
Operating Range, Grid Frequency |
fAC |
59.3 Hz - 60.5 Hz |
|
Phase Shift (Ref. Fundamental) |
cos(phi) |
0° |
|
Output Values (277V) |
|
|
|
Max AC Power |
PAC |
6000 W |
|
Total Harmonic Distortion |
THDIAC |
< 4% (With KVgrid < 2% and PAC > 0.5 PACnom) |
|
Operating Range, Grid Voltage |
VAC |
244 V to 305 V |
|
Operating Range, Grid Frequency |
fAC |
59.3 Hz - 60.5 Hz |
|
Phase Shift (Ref. Fundamental) |
cos(phi) |
0° |
|
Output Protection |
|
|
|
Islanding Protection |
|
VAC; FAC designed to meet the requirements of UL 1741 |
|
Ground Fault Protection |
|
IDIF; designed to mee the requirements of UL 1741 |
|
A C Disconnect |
|
External AC Breaker |
|
Short Circuit Protection |
|
Current Controlled |
|
Overvoltage Classification |
|
III |
|
Efficiency |
|
|
|
Peak Efficiency |
|
95 % (Rebate Efficiency) |
|
Power Consumption |
|
|
|
Internal consumption in operation |
|
< 7 W |
|
Internal consumption at night |
|
0.25 W |
|
American Standards |
|
|
|
Hardware Safety |
|
Designed to meet the requirements of UL 1741 |
|
Firmware Safely |
|
Designed to meet the requirements of UL 1998 |
|
Power Quality |
|
IEEE 519 |
|
Anti-Islanding |
|
IEEE 929 |
|
Electro-Magnetic Interference |
|
FCC Part 15 A & B |
|
Size and Weight |
|
|
|
Width |
|
430 mm (16.9 in) |
|
Height |
|
600 mm (23.6 in) |
|
Depth |
|
250 mm (9.8 in) |
|
Weight |
|
63 kg (139 lbs) |
|
Enclosure Ratings |
|
|
|
NEMA Rating |
|
NEMA 3R |
|
Ambient Conditions |
|
|
|
Ambient Temperature Range |
|
-13°F to +140°F or -25°C to +60°C |
|
Relative Humidity Level |
|
0 to 100% |
Contact Us:
Telephone: toll free at 1-888-810-4709
Parry
Sound,Northern
Ontario,Muskoka and Georgian Bay
Ontario,Canada
© Copyright 2005, Enviroharvest Inc.™
All Rights Reserved
Caribbean and US |