Inverter Specifications

ME2012

ME2512

ME3112

Input battery voltage range

9 - 16 VDC

Nominal AC output voltage

120 VAC

Output frequency and accuracy

60 Hz ± 0.005%

1 msec surge current (amps AC)

60

100

120

100 msec surge current (amps AC)

37

45

50

5 sec surge power (real watts)

3700

5000

6000

30 sec surge power (real watts)

3450

4500

4800

5 min surge power (real watts)

3100

3500

3950

30 min surge power (real watts)

2400

2900

3500

Continuous power output at 45° C

2000 VA

2500 VA

3100 VA

Rated input battery current

191.0 ADC

239.1 ADC

296.5 ADC

Inverter efficiency (peak)

95%

91%

90%

Transfer time

16 msecs

Search mode

.2 ADC

No load (120 VAC output)

0.87 ADC

0.95 ADC

0.97 ADC

Waveform

Modified Sine Wave

Charger Specifications

 

Continuous output at 45° C

100 ADC

120 ADC

160 ADC

Charger efficiency

85%

Power factor

> .95

Input current at rated output (AC amps)

15

18

21

General Features and Capabilities

 

Transfer relay capability

2 legs at 30 A for 120 V/30 A or 240 V/60 A service

 

Five stage charging capability

Bulk, Absorb, Float, Equalize, and Battery Saver™

 

Battery temperature compensation

With available temp sensor (battery temp 0 - 50° C)

Remote inverter on/off switch

With available pigtail to connect to dry contact

Internal cooling

 0 to 120 cfm variable speed drive using dual 92mm brushless DC fans

Over current protection

Yes, with two overlapping circuits

Over temperature protection

Yes on transformer, MOSFETS, and battery

Conformal coating on PCB’s for corrosion protection

Yes

Powder coated chassis & top for corrosion protection

Yes

Stainless steel fasteners for corrosion protection

Yes

Dual AC branch rated output breakers

Optional on the ME2012 - AC breakers in 15 or 20 amp ratings

Series stacking interface 120/240 V

Yes

Listings

ETL Listed to UL/cUL 458, CSA C22.2 #107.1-01

Warranty

Three (3) years

Environmental Specifications

 

Operating temperature

-20° C to +60° C (-4° F to 140° F)

Non operating temperature

-40° C to +70° C (-40° F to 158° F)

Operating humidity

0 to 95% RH non condensing

Physical Specifications

 

Dimensions (h x w x d)

13.75” x 12.65” x 8.0” (34.9 cm x 32.1 cm x 20.3 cm)

Mounting

Shelf (top or bottom up) or bulkhead (vents up)

Weight

38 lb (17 kg)

42 lb (19 kg)

45 lb (20 kg)

Max operating altitude

15,000’ (4570 m)

Home Up Products Saving Energy Glossary Contents About / Contact

We treat customers in the way we would like to be treated.

Contact Us: Telephone:  toll free at 1-888-810-4709 Parry Sound,Northern Ontario,Muskoka and Georgian Bay
Send mail to:
info@enviroharvest.ca with questions or comments about our product or web site.

Ontario,Canada © Copyright 2005, Enviroharvest Inc.    All Rights Reserved Caribbean and US
Last modified: July 08, 2010